Approvals Data
Many customers have requested information on EN standards and UL listings etc. Your feedback is important and here is the result!
- Meeting the EN Standards A short table for all of our standard platforms.
- Kaschke Isolation System UL 1446 an explanation of how we approach and comply to UL standards.
- UL listing of materials
All of our standard parts on the website for isolation barrier transformers comply.
A step forward in removing the approvals headache for this part in your design at least.
MEETING THE EN Standards
| Kaschke Platform |
EN Norms |
Creepage Distance |
| |
|
|
| SP-E13/6 |
EN60950/EN61558
|
6.4mm
|
| SP-E16/5 |
EN60950/EN61558
|
8mm
|
| SP-E20/6 |
EN60950/EN61558
|
8mm
|
| SP-E25-7 |
EN60950/EN61558
|
8mm
|
| SP-E30/7 |
EN60950/EN61558
|
6.4mm std to 8mm upon request
|
| SP-36/11 |
EN60950/EN61558 |
6.4mm std to 8mm upon request
|
EN60950 and EN61558 are the standard specifications we work to as a transformer manufacturer. The following EN norms apply to the finished product but we can state that our designs will meet the standards you require. Please call to discuss the exact classification you require.
EN60 065 (Brown Goods) EN60335 (White Goods & Battery Chargers)
Although all of the Kaschke platform parts are constructed to meet the basic standard, care must be taken to check your individual specification as the standard does change with higher working voltages and or Class levels.
As an example EN60335 Class II states a 6mm creepage. However if you require Class III then you require 8mm creepage.
Kaschke Isolation System UL 1446
As a manufacturer of an isolation barrier for a transformer Kaschke have now been approved to meet the UL standard. The hyper link below can take you directly to the site listing.
The vast majority of Kaschke Smartpower transformers are constructed using UL listed material with our default design to KIS-03.
The KIS-03 level meets the isolation levels and to a temperature of 130 degrees C.
There are two further levels that we can also manufacture to but they are normally custom designs.
KIS-02 Potted transformers
KIS-01 155 degree C operating temperature
Please follow this link for further information
Link To UL Qualification
UL listing of materials
If you require a listing of the UL parts within our construction. We will be glad to help and provide a spreadsheet indicating the materials used and their relevant UL number. Certificates KIS-ME01 - KIS-ME02 - KIS-ME03
Please contact us via email on rotima@rotima.ch |